A leading global expense management and relocation software company that services a wide range of clientele. Experts in tax regulations and relocation. How To Use Orion Software System' title='How To Use Orion Software System' />RHYTHMIA HDx Indications, Safety and Warnings. Indications, Safety and Warnings. Return to Product Page. UserFiles/tiny_files/Orion_install/4.png' alt='How To Use Orion Software System' title='How To Use Orion Software System' />Prescriptive Information. CAUTION Federal law USA restricts this device to sale by or on the order of a physician. Rx only. Prior to use, please see the complete Directions for Use for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events, and Operators Instructions. RHYTHMIA Mapping System. INTENDED USEINDICATIONS FOR USEThe Rhythmia Mapping System and accessories are indicated for catheter based atrial and ventricular mapping. The mapping system allows real time visualization of intracardiac catheters as well as display of cardiac maps in a number of different formats. The acquired patient signals, including body surface ECG and intracardiac electrograms, may also be recorded and displayed on the systems display screen. CONTRAINDICATIONSThere are no known contraindications. WARNINGS AND PRECAUTIONSThe use of the Rhythmia Mapping System in conjunction with radio frequency ablation and other medical devices, as a part of the diagnosis and treatment of cardiac arrhythmias, may pose a risk of adverse events, such as cardiac perforation and arrhythmias new andor exacerbation of existing arrhythmias that may require additional intervention. Do not operate the Rhythmia Mapping System near flammable anesthetics. Take a closer look with the included 10mm Sirius Plossl Eyepiece. How To Uninstall Windows Xp In Vmware Workstation Player. When youre ready to study objects with more magnification, use the included 10mm Sirius Plossl. Comprehensive Law Practice Management. Since 1985, Orion Law Management Systems has developed and implemented powerful firm management software that delivers rapid. Project Orion was the first serious attempt to design a nuclear pulse rocket. The design effort was carried out at General Atomics in the late 1950s and early 1960s. April 2013 Jung 20, 44 A. T. The Best of the Year Polls 2012 Heres your chance to vote in the Second of the Orions Arm 2012 Best of the Year Awards. System operation near flammable anesthetics may cause an explosion that could cause injury or death to the patient or user. All devices that are connected to the Rhythmia Mapping System must meet IEC 6. When connected to other devices, the combined systems configuration must meet the IEC 6. The use of the Rhythmia Mapping System with accessories and devices that do not comply with relevant standards may reduce the safety of the system, cause equipment damage or system malfunction, or harm to the patient or user. Only stimulators that are certified for IEC 6. Rhythmia Mapping System. Do not connect life sustaining pacing through the Rhythmia Mapping System. The system is not intended to provide life sustaining therapy and should not be used as such. In case of need for emergency pacing, or any failure of stimulator routing, directly connect the desired paced channel to the stimulator. The Rhythmia Mapping System is only designed to route the stimulation signal to the desired channel. To start or stop stimulation, always use the controls on the external stimulator. Use the Rhythmia Mapping System only with one of the following RF ablation generators Maestro 3. Stockert, or IBI. Do not use the system with other RF ablation generators. Compatibility with other RF ablation generators has not been demonstrated. Do not apply RF energy larger than 1. W to ablation catheters that are connected to the Maestro 3. RF generator and the Rhythmia Mapping System. Do not apply RF energy larger than 7. W to ablation catheters that are connected to the Stockert RF generator and the Rhythmia Mapping System. Do not apply RF energy larger than 5. W to ablation catheters that are connected to the IBI RF generator and the Rhythmia Mapping System. To reduce the risk of electric shock or equipment damage, do not clean the Rhythmia Mapping System when it is plugged in, turned on, or connected to a patient. Cleaning the system while it is in use and connected to a power source may cause an electrical shock that could cause injury or death to the patient or user. To reduce the risk of electric shock, assure that any ECG cables and electrodes are not in contact with any other conductive parts, including ground. To reduce the risk of electric shock during defibrillation, assure that the exposed connector tips on the ECG output box are covered at all times with the protective, non conductive material provided with the ECG output boxes. Do not use the ECG output box if the protective cover is damaged see ECG Output Box. The system generates electrical impedance fields as part of its normal operation. Do not use other systems that also generate electrical impedance fields in the same procedure, as this may interfere with the systems normal operation and reduce the quality of catheter localization, and signals. Magnetic Localization System. Do not operate the Localization Generator within 2. CIEDs. Doing so may affect pacing, temporarily suspend tachycardia therapy delivery, or lead to patient discomfort. Signal Station. To minimize the risk of electric shock, connect the Signal Station only to supply mains with a protective ground earth connection. Use only a functioning, properly tested supply main with protective ground earth to power the Rhythmia Mapping System. The use of a faulty, ungrounded supply main increases the risk of electrical shock and system malfunction. To minimize the risk of electric shock, prior to using the Rhythmia Mapping System, connect the equipotential socket located on the Signal Station rear panel to a common ground. This connection grounds the Rhythmia Mapping System and must remain connected at all times see Signal Station Setup in the DFU. The Signal Station requires a dedicated, 2. V DC power supply, which is provided by Boston Scientific with the Signal Station. To reduce the risk of Signal Station damage, use only the power supply provided by Boston Scientific for use with the Signal Station. To reduce the risk of Signal Station damage, do not connect or disconnect the Signal Station to its power supply while the Signal Station is turned on. To minimize potential exposure to water or liquid, prevent fluids from entering air vents. Do not place beverages or containers of water or liquid directly on or near the Signal Station or other system components. Do not block the air vent on the Signal Station during Signal Station use. Blocking the air vent during Signal Station use can cause the Signal Station to overheat, which may affect system operation. Use only a flat stable surface to hold the Signal Station and Signal Station related accessories. Workstation. To minimize potential exposure to water or liquid, do not place beverages or containers of water or liquid directly on or near the Workstation or other system components. Use only a flat stable surface to hold or transport the Workstation and Workstation related accessories. To prevent loss of data, frequently back up the data by archiving cases no longer needed for immediate access. Cables. Use only the ECG cables supplied by Rhythmia Medical for use with the Rhythmia Mapping System. ECG cables provided by Rhythmia Medical are designed and tested to protect the Signal Station from defibrillation energy. Using other ECG cables may cause serious damage to the system hardware. Prior to using the Rhythmia Mapping System, inspect all external connections and cable connectors. Make sure all connections are secure. Tighten any loose connections prior to using the system. Do not use excessive force when connecting or disconnecting cable connectors. Excessive force can damage the connectors, which may cause system malfunction. Do not kink or sharply bend cables. Kinks and sharp bends can damage the cables, which may cause system malfunction. To minimize the risk of damage, store unused system cables in a clean, dry, and secure location, consistent with storage guidelines see Equipment Storage Transporting in the DFU. Electrical. Never use ungrounded electrical outlets to power any system components. Do not use extension cords or adapters for ungrounded outlets. High quality valves for the petrochemical industries. ORION present their product line of Steel Valves incorporating new and revised. The Company has a world market distribution network and sells. Y pattern and Bellows seal and valves for specialised services such as Alkylation. Cryogenic and Lethal service. The best quality materials and engineering. All ORION valves are produced by employing the best raw materials, carefully selected, correctly. The machining is carried out with the aid of the latest type equipment. All ORION products are constantly tested and inspected to. ORION valves are designed.